BGGRP - HYSOL HD5009 CATALYST 9

Product Identification

Product ID:HYSOL HD5009 CATALYST 9
MSDS Date:08/27/1991
FSC:7510
NIIN:01-036-3724
MSDS Number: BGGRP

Responsible Party
DEXTER ELECTRONIC MATERIALS DIV
15051 E DON JULIAN RD
INDUSTRY, CA 91749-1282
US

Emergency Phone: 818-916-9107

Info Phone: 818-968-6511

Preparer: RICHARD L. HALL

Cage: 04347

Contractor
DEXTER CORP THE DEXTER ELECTRONIC MATERIAL DIV
OLEAN, NY 14760-1297 US

Telephone: 716-372-6300/6309

Cage: 04347

Ingredients

TETRAETHYLENEPENTAMINE

CAS: 112-57-2

RTECS: KH8585000

Fraction By Weight: 35-60%


2-BUTOXYETHANOL (ETHYLENE GLYCOL MONOBUTYL ETHER), BUTYL

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 35-60%

OSHA PEL 50 PPM (SKIN)

ACGIH TLV: 25 PPM (SKIN)


417 G/L (3.48 LB/GL)

RTECS: 9999999VO

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT): 470 MG/KG (SEE SUPP)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: SEVERE IRRITATION, CORNEAL
INJURY, PERMANENT VISION IMPAIRMENT, BLINDNESS. SKIN: BURNS,
ALLERGIC REACTION, ABSORPTION LEADING TO DEATH. INHALATION: UPPER
RESPIRATORY IRRITATION & SENSITIZATION, IN VITRO MUTAGENICITY &
BLOOD, LUNG, LIVER & KIDNEY EFFECTS. INGESTION: GI
IRRITATION/ULCERATION, MOUTH & THROAT BURNS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, BURNS, SENSITIZATION

First Aid

First Aid:EYES: FLUSH W/PLENTY OF WATER AT LEAST 30 MINS. SKIN: FLUSH
W/PLENTY OF WATER AT LEAST 15 MINS. INHALATION: REMOVE TO FRESH
AIR. ADMINISTER OXYGEN/CPR IF NEEDED. INGESTION: FOR TETRAETHYLENE
PENTAMINE , DON'T INDUCE VOMITING. GIVE LARGE QUANTITIES OF WATER
TO DILUTE. FOR ETHYLENE GLYCOL MONOBUTYL ETHER, INDUCE VOMITING IF
LARGE AMOUNTS ARE INGESTED. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point Method:SCC
Flash Point:175F
Extinguishing Media:CO2, FOAM, DRY CHEMICALS
Fire Fighting Procedures:PERSONNEL ENGAGED IN FIGHTING FIRES SHOULD
WEAR SCBA.

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES. PROVIDE ADEQUATE
VENTILATION. COVER W/ABSORBENT MATERIAL & REMOVE TO WASTE
CONTAINER.

Handling

Handling and Storage Precautions:STORE IN CLOSED CONTAINERS IN A COOL
DRY AREA AWAY FROM HEAT. USE ONLY W/ADEQUATE VENTILATION.
Other Precautions:AVOID PROLONGED/REPEATED BREATHING OF VAPORS/CONTACT
W/SKIN.

Exposure Controls

Respiratory Protection:WEAR PROPERLY FITTED NIOSH/MSHA APPROVED
SCBA/INDUSTRIAL TYPE CANISTER MASK IN ENCLOSED AREAS W/POOR/NO
VENTILATION SYSTEM.
Ventilation:LOCAL EXHAUST IS PREFERRED, MECHANICAL ACCEPTABLE.
Protective Gloves:HYDROCARBON INSOLUBLE RUBBER/PLASTIC
Eye Protection:CHEMICAL GOGGLES, FACE SPLASH SHIELD
Other Protective Equipment:SAFETY GLASSES, HYDROCARBON INSOLUBLE
APRONS, EYE WASH, SAFETY SHOWER
Work Hygienic Practices:REMOVE & LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. DESTROY CONTAMINATED SHOES.
Supplemental Safety and Health
ORAL LD50 DATA GIVEN FOR ETHYLENE GLYCOL MONOBUTYL ETHER.

Chemical Properties

Boiling Pt:B.P. Text:300F
Spec Gravity:0.95
Appearance and Odor:LIGHT AMBER LIQUID W/MILD AMINE ODOR
Percent Volatiles by Volume:50/WT

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS
Stability Condition to Avoid:HIGH TEMPERATURE, OPEN FLAMES
Hazardous Decomposition Products:CO, CO2, OXIDES OF NITROGEN

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/FEDERAL, STATE &
LOCAL ENVIRONMENTAL CONTROL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.